Connection to cold water or reduced voltage can extend the heating time and the programme runtime.
We recommend an external water softener for feed water hardness above 3°dH.
The installation of machines with integrated water softener requires a back flow safety device (at site) according to DVGW-DIN 1988.
Required supply pressure: with integral rinse pressure pump: 0.8 to 10 bar; without integral rinse pressure pump: 2 to 6 bar
Cycle times* | 75 / 150 / 180 sec |
Capacity per hour* | up to 48 racks |
Wash / rinse temperature | approx. 60 °C / approx. 82 °C |
Tank capacity | 21 l |
Fresh water consumption / cycle | 2.3 l |
Wash pump | 0.4 kW |
Heating booster / tank | H604-10B: 5.5 (3.7**) kW / 2.5 kW; H604-12B: 6.2 (4.1**) kW / 2.5 kW; H604-33B 10 kW / 2.2 kW |
Total loading | H604-10B: 6.0 (4.1**) kW; H604-12B: 6.6 (4.6**) kW; H604-33B 11 kW |
Rated voltage | 400V / 50hz / 3N (230V / 50hz / 1) |
Width / Depth / Height | 635 / 742 / 1,480 (1,960 open) mm |
Loading height | 440 mm |
Rack size | 500 x 500 mm |
* hot water connection
** 230V/50Hz/1/N
60 Hz versions are available for an extra charge (min. lot size of 5 machines).